WebOct 22, 2014 · E Nash – TP – 08/ REV 0 PROCEDURE FOR SURFACE PREPARATION AND PROTECTIVE COATING PAGE 5 O F 7 2, ISO-12944 and ISO-2808. Maximum allowable, dry … WebFor a 67% volume solids material with a WFT of 18 mils, DFT = 18 x 0.67 = 12 DFT. By simply reversing the equation DFT can also be measured to determine what the applied WFT …
(PDF) Document Title SURFACE PREPARATION
WebCoating thickness measurement on ferrous and non-ferrous metals. Measures using the phase-sensitive eddy current method. Measurement range of 0 – 3000 μm. Robust IP65-compliant housing protects the sensitive electronics from harsh conditions Conforms to these standards: DIN EN ISO 2360, ASTM D7091, DIN EN ISO 2178 and DIN EN ISO 21968. WebMaximum & Minimum DFT. Good practice from paint company guidelines would mean that the maximum DFT applied should be two times the specified DFT for each coat and for … free children\u0027s easter coloring pages
Anas Alali - Coating Manager - Blasting & Painting
SSPC-PA 2 was originally published as a temporary standard 40 years ago in 1973 (73T) as “Measurement of Dry Coating Thickness with Magnetic Gages.” The standard referenced gages like the one shown in Fig. 1, which are now all but obsolete. The standard has been updated on multiple occasions. … See more SSPC-PA 2 addresses two types of DFT gages, both of which are supplied by a variety of manufacturers. Magnetic pull-off gages are categorized as Type 1 (Fig. 2). These gages were designed in the 1950s. While their use has … See more To help assure the reliability of the coating thickness measurements, ASTM D 7091 describes three operational steps that must be performed before taking the measurements. These … See more The accuracy of Type 1 (magnetic pull-off) gages is verified by placing the gage probe onto a certified coated thickness standard (Figs. 4 and 5). A one-point or two-point accuracy verification … See more To guard against measuring with an inaccurate gage, SSPC-PA 2 requires that gage accuracy be verified (at a minimum) at the beginning and end of each work shift according to the procedures described in ASTM D … See more WebJun 12, 2015 · Calculate the required WFT to obtain minimum specified DFT. Spray the paint on a sample plate / beam to ensure that correct atomization and flow of paint is obtained … WebOct 8, 2015 · Consumption = = litreArea (m2) x DFT. 10 x % VS. To be painted: Tank, area of 500 m2. Paint School9. Consumption of paint, no loss (1 of 2) Epoxy mastic = 117,7 litre. … free children\u0027s games for windows 7